Popping Breakers

Simple Questions:

Electric Manual Model 2 (4-LED) Model 2 (5-LED)
05/08 15/18/15C 25/28/25C 45/48/25/28/23/25C

 

 

 

 

 

 

 

 

 


05, 08 Test

Eliminating components to see which is causing breaker to pop.

  • Unplug machine.
  • Disconnect heater and pump wires from control panel (the panel is labeled). 
  • Plug machine back into power source and see if unit will power up without popping breaker.
  • Is it pops, the control panel is defective; if not, UNPLUG machine, re-connect the pump wires, then REPLUG machine (REMEMBER proper startup procedures).
  • If pops, pump is defective; if not, do the same thing again with the heater connections.
  • If pops, the heater is defective.
 

Back to top

 

 

 

 

 

 

 

 

 

 


Component is controlled by Thermostat Switch

If reset button keeps popping, please call ChemFree tech support at 1-800-521-7182

Back to top

 

 

 

 

 

 

 

 

 

 

 


Store's Circuit Popping:  (Note:  If the SW has a GFCI switch, it cannot be the SW itself causing the issue)

- Ensure the store’s line is not being overloaded. Have them plug SW into a different outlet on a different line.
- If it's still popping, select machine below:

 

Electric Manual Model 2
05/08 15/18/15C 25/28/25C/23

 

 